Short answer
A QR code has 40 versions from 21 × 21 to 177 × 177 modules[3][2] and four error-correction levels that restore roughly 7% (L), 15% (M), 25% (Q) and 30% (H) of damaged codewords[4]. Byte capacity at level M runs from 14 bytes at version 1 to 2,331 at version 40 (NexaLink measurement with qrcode 1.5.4)[1]. A 28-byte card link needs version 3 (29 modules); with a 4-module quiet zone and 0.5 mm modules that is 18.5 mm a side — comfortably on an 89 × 51 mm card. A 438-byte vCard needs version 16 (81 modules, 44.5 mm).
Key takeaways
- Version is set by payload bytes and level; modules per side = 17 + 4 × version[3]. Nothing else about the code's size is negotiable except the physical size of a module.
- Raising error correction from L to H costs capacity: at version 10 the limit falls from 271 bytes to 119 (measured)[1]. On a business card, which is not going to be scratched, M is the usual trade-off; H is for logos overlaid on the code.
- The quiet zone — a 4-module clear border on all sides — is part of the standard[2] and is the most common thing designers cut.
- The 0.5 mm module size used in the examples is NexaLink's working assumption for phone cameras at arm's length; the standard does not prescribe a print size, so test the real distance.
- A link in the code and the contact on the page keeps the code at version 2–3; a full vCard quadruples its area.
QR version and print size — calculator
Paste what the code will contain (a link, a vCard, a MECARD). The calculator counts bytes, finds the smallest version that holds them at the chosen error-correction level and converts modules to millimetres at your module size.
- Bytes
- 28
- Version
- 3
- Modules per side
- 29
- Printed side incl. quiet zone
- 18.5 mm
Method: capacity table measured with qrcode 1.5.4 (byte mode); modules per side = 17 + 4 × version; printed side = (modules + 2 × 4-module quiet zone) × module size. Maximum payload at level M is 2,331 bytes (version 40).
Capacity table: bytes per version and level (measured)
We measured capacity by encoding runs of ASCII bytes with the qrcode 1.5.4 encoder[1] and binary-searching the largest payload each fixed version accepts at each level, on 15 November 2026. The end points match the published figures for ISO/IEC 18004 (for example 2,953 bytes at version 40, level L)[3][2], which is the check that the encoder follows the standard. Byte mode is the right column for URLs and vCards; numeric and alphanumeric modes pack more characters into the same version but cannot carry lower-case letters or most punctuation.
| Version | Modules | L | M | Q | H |
|---|---|---|---|---|---|
| 1 | 21 × 21 | 17 | 14 | 11 | 7 |
| 2 | 25 × 25 | 32 | 26 | 20 | 14 |
| 3 | 29 × 29 | 53 | 42 | 32 | 24 |
| 4 | 33 × 33 | 78 | 62 | 46 | 34 |
| 5 | 37 × 37 | 106 | 84 | 60 | 44 |
| 6 | 41 × 41 | 134 | 106 | 74 | 58 |
| 7 | 45 × 45 | 154 | 122 | 86 | 64 |
| 8 | 49 × 49 | 192 | 152 | 108 | 84 |
| 9 | 53 × 53 | 230 | 180 | 130 | 98 |
| 10 | 57 × 57 | 271 | 213 | 151 | 119 |
| 12 | 65 × 65 | 367 | 287 | 203 | 155 |
| 14 | 73 × 73 | 458 | 362 | 258 | 194 |
| 16 | 81 × 81 | 586 | 450 | 322 | 250 |
| 18 | 89 × 89 | 718 | 560 | 394 | 310 |
| 20 | 97 × 97 | 858 | 666 | 482 | 382 |
| 25 | 117 × 117 | 1,273 | 997 | 715 | 535 |
| 30 | 137 × 137 | 1,732 | 1,370 | 982 | 742 |
| 35 | 157 × 157 | 2,303 | 1,809 | 1,283 | 983 |
| 40 | 177 × 177 | 2,953 | 2,331 | 1,663 | 1,273 |
What error correction actually buys
QR codes use Reed–Solomon error correction; the four levels let a reader reconstruct the data when part of the symbol is dirty, torn or covered. DENSO WAVE, the inventor, gives the approximate recovery capacity as L about 7%, M about 15%, Q about 25% and H about 30% of codewords[4]. The price is capacity: the same version holds fewer data bytes at a higher level, as the table shows, so a given payload needs a larger version and therefore a bigger print.
| Payload | Bytes | L | M | Q | H | Area at H vs L |
|---|---|---|---|---|---|---|
| Short link | 28 | v2 (25) | v3 (29) | v3 (29) | v4 (33) | 1.74× |
| Minimal vCard 3.0 | 124 | v6 (41) | v7 (45) | v9 (53) | v11 (61) | 2.21× |
| Full vCard 3.0 | 438 | v14 (73) | v16 (81) | v19 (93) | v22 (105) | 2.07× |
From modules to millimetres
Printed side = (modules per side + 2 × 4-module quiet zone) × module size. The quiet zone is the clear margin the standard requires around the symbol[2]; a code printed to the edge of a coloured panel loses it. The module size is the one variable the standard leaves to you, because it depends on the printer, the paper and the scanning distance. We use 0.5 mm as a working assumption for a phone camera at reading distance; it is an assumption, and a code for a poster or a shop window needs much larger modules. Test the real code on the real print at the real distance before ordering 500 cards.
| Payload (level M) | Modules | 0.4 mm modules | 0.5 mm modules | 0.6 mm modules |
|---|---|---|---|---|
| Short link (28 B) — v3 | 29 | 14.8 mm | 18.5 mm | 22.2 mm |
| MECARD (88 B) — v5 | 37 | 18.0 mm | 22.5 mm | 27.0 mm |
| Minimal vCard (124 B) — v7 | 45 | 21.2 mm | 26.5 mm | 31.8 mm |
| Typical vCard (280 B) — v12 | 65 | 29.2 mm | 36.5 mm | 43.8 mm |
| Full vCard (438 B) — v16 | 81 | 35.6 mm | 44.5 mm | 53.4 mm |
The practical conclusion is the one NexaLink Card is built on: put a short link in the printed code and keep the contact details on the page it opens, which can also offer a vCard download. See vCard and MECARD formats for what goes inside and NFC vs QR business cards for how the two sharing methods compare on real phones. To make a code now, the free QR code business card tool uses these rules.
Frequently asked questions
What is the minimum size for a QR code on a business card?
It depends on the payload. A short link (28 bytes) is QR version 3 at level M: 29 modules plus a 4-module quiet zone each side. At 0.5 mm modules that is 18.5 mm a side; at 0.4 mm, 14.8 mm. Test the scan distance on a real print; the standard sets no millimetre figure.
Which error correction level should I use?
M for most printed cards: about 15% recovery for a modest size increase. Use H (about 30%) only if a logo or design element will cover part of the code. L is for codes shown on screens where damage is not a concern.
How much data can a QR code hold?
In byte mode, measured with qrcode 1.5.4: 2,953 bytes at version 40 level L, 2,331 at M, 1,663 at Q and 1,273 at H. Version 1 holds 17, 14, 11 and 7 bytes respectively.
What is the quiet zone?
The clear margin of four modules on every side of the symbol required by ISO/IEC 18004. Cropping it is the most common reason a code that looks fine will not scan.
Does a vCard QR code fit on a business card?
A minimal one (name, phone, email) does: version 7, 45 modules, 26.5 mm at 0.5 mm modules. A full one (438 bytes) is version 16, 81 modules and 44.5 mm — almost the whole short side. A link is 18.5 mm.
Why do your capacity numbers come from a software library?
Because measuring them is reproducible and the end points match the standard's published limits, which is the check that the encoder follows ISO/IEC 18004. The standard itself is paid; the DENSO WAVE pages and the encoder are free to check.
Sources
- npm — qrcode 1.5.4 (QR code encoder used for the measurements) — checked on 2026-11-15
- ISO/IEC 18004:2024 — QR code bar code symbology specification (edition 4, August 2024) — checked on 2026-11-15
- DENSO WAVE qrcode.com — Information capacity and versions of the QR Code — checked on 2026-11-15
- DENSO WAVE qrcode.com — Error correction feature — checked on 2026-11-15